ISO 15189 accreditation, without the mental load

8 min read

October 2, 2026

Cells seen under a microscope (illustration)

Being accredited to the ISO 15189 standard means being able to demonstrate control of your processes at any time: who did what, when, on which sample, with which controls. As early as 2013, an article in Biologiste Infos on the LIS market presented these requirements, together with the consolidation of laboratories, as a challenge that smaller vendors might not meet. Yet much of this evidence can be produced by the software itself, as activity unfolds. In France, ISO 15189 accreditation is in fact mandatory for clinical laboratories.

ISO 15189 accreditation: a requirement for laboratories

Ordinance No. 2010-49 of 13 January 2010 on clinical biology, ratified by Law No. 2013-442 of 30 May 2013, made accreditation mandatory (Article L. 6221-1 of the French Public Health Code), as the French National Authority for Health (HAS) points out. It is granted by the French Accreditation Committee (COFRAC), created in 1994 and the sole reference body for accreditation in France.

The standard applies to clinical laboratories, but also to other medical laboratories such as anatomic and cytologic pathology facilities. COFRAC sets out its requirements in document SH REF 02.

ISO 15189:2022: what has changed

Published on 6 December 2022, the fourth edition of the standard, “Medical laboratories — Requirements for quality and competence”, replaces ISO 15189:2012 and incorporates point-of-care testing, previously covered by ISO 22870. Its structure is aligned with that of ISO/IEC 17025:2017, and it places greater emphasis on patient care, through the planning and implementation of actions to manage risks.

In France, COFRAC carried out the first assessments against the 2022 version from 1 October 2023. Since 1 October 2025, only the revision of SH REF 02 based on the 2022 standard remains applicable, and the transition period ended in December 2025.

What COFRAC looks at in the IT system

COFRAC has published a dedicated technical guide, SH GTA 02, for the assessment of IT systems in clinical biology (applicable since July 2013). It covers in particular:

  • data traceability;
  • hierarchy of access rights and locking after inactivity;
  • data backup and archiving verification;
  • verification of configuration (tests, coded texts, connections, rules) and of alarms transmitted by analyzers;
  • inventory of remote connections.

For analytical methods, guide SH GTA 04 explains the requirements for verification (scope A) and validation (scope B) of clinical biology methods.

Trace everything, without thinking about it

TECHNIDATA software includes an audit system that records who did what, when and where, on patient data, test requests and samples. This traceability builds up as activity unfolds. In genetics, TDGenet even lets the laboratory define the desired level of traceability.

In a group of two hospitals in the Grand Est region, the traceability of TDNexLabs (who did what and when, for each record) supports the ISO 15189 accreditation process. TDNexLabs also archives in PDF format a copy of the report sent to the ordering physician, in line with ISO 15189 recommendations.

Just the right access

Fine-grained rights management preserves the confidentiality of results: each user only accesses the data needed for their role and laboratory. In TDNexLabs, access rights and user profiles are based on a centralized directory service. Rights can depend on the origin of the request and on the user's laboratory, while still showing results from other disciplines in a single patient record.

Non-conformities: from recording to corrective action

A non-conformity should not end up in a binder. The software makes it possible to record it, track the resulting corrective and preventive actions, and manage the entire life cycle of quality documents. Non-conformity management is available in the microbiology solutions (with document management), genetics and BRC management solutions.

Indicators make it possible to monitor their handling, and document management covers the creation, approval, update and distribution of documents. At the Grand Hôpital de l'Est Francilien, which is aiming for accreditation in the long term, the TDHistoCyto upgrade notably improved non-conformity management.

Quality control and method validation

On the technical platform, TDMind centralizes the monitoring of analyzer quality control:

  • target value tables, histograms, Levey-Jennings charts and Westgard rules;
  • management of the probationary period and of laboratory, supplier or calculated target values;
  • assisted entry: locking of the CV or standard deviation, automatic calculation during entry, reuse of values from an existing lot;
  • export of quality control reports to a third-party system or to external quality control.

Its method validation module automatically generates SH-FORM reports to meet the requirements of the ISO 15189 standard. TDMind also lets you choose which run to keep, keeps the raw value before any conversion as well as the analyzer's flags and alarms, and traces lots when the protocol allows it.

Expert rules: automate, but under control

Expert rules automate routine tasks and standardize methods. In TDNexLabs, a validation system makes it possible to check them before they go into production, in line with the ISO 15189 standard. This system also makes it possible to simulate results as if they were transmitted by the analyzers. In TDMind, a graphical interface is used to create them and a simulation mode to test them.

Monitor, alert, measure

TDNexLabs sends targeted alerts by SMS or e-mail: critical results in clinical biology, nosocomial infections in microbiology. Real-time dashboards monitor activity, performance and result turnaround times.

Each discipline has its own requirements

  • Microbiology: TDBactiLink makes it possible to design paperless workflows adapted to microbiology, with exhaustive traceability that meets the requirements of the ISO 15189 standard.
  • Genetics: TDGenet facilitates the ISO 15189 accreditation process of genetics laboratories, thanks to its traceability and non-conformity management.
  • Anatomic pathology: TDHistoCyto complies with College of American Pathologists (CAP) requirements and follows the ADICAP and SNOMED® standards.
  • BRCs and biobanks: TDBioBank supports both NF S 96-900 certification and ISO 15189 accreditation.

A precedent: the Emile Gallé Center

In its March-April 2014 issue, the British magazine NHE, in an article on laboratory accreditation, mentioned the Emile Gallé Anatomic Pathology Center in Nancy. Drs Maud Ounnoughene and Stéphane Kirchner, associate pathologists at the center, explained how TECHNIDATA's anatomic pathology software had helped make the center the first anatomic pathology facility in Europe to be accredited to NF EN ISO 15189.

And after the audit?

Accreditation does not stop with the visit. A dedicated quality unit answers laboratories' questions after their COFRAC audits, and provides them with a library of answers to possible IT non-compliances.

ISO 15189 accreditation: what to check in your software

  • a complete audit trail (who, what, when, on which record) and role-based access rights;
  • management of non-conformities, corrective actions and quality documents;
  • quality control monitoring and method verification reports;
  • validation of expert rules before they go into production;
  • archiving of reports and vendor support after audits.

Frequently asked questions

Is ISO 15189 accreditation mandatory?

Yes, for clinical laboratories in France: Ordinance No. 2010-49 of 13 January 2010, ratified by Law No. 2013-442 of 30 May 2013, made it mandatory (Article L. 6221-1 of the French Public Health Code). It is granted by COFRAC.

What changes with ISO 15189:2022?

Published in December 2022, this version replaces the 2012 edition and incorporates point-of-care testing, previously covered by ISO 22870. It places greater emphasis on risk management. In France, only the revision of SH REF 02 based on the 2022 standard has applied since 1 October 2025.

What does COFRAC check in the IT system?

Its technical guide SH GTA 02, applicable since 2013, details the assessment of IT systems in clinical biology: data traceability, hierarchy of access rights, backup and archiving, verification of configuration (tests, connections, business rules, analyzer alarms) and remote connections.

Is software enough to be accredited?

No: accreditation concerns the laboratory, which is assessed by COFRAC. The software, however, provides much of the evidence as activity unfolds: audit of actions, access rights, non-conformities, quality control. At TECHNIDATA, a quality unit also supports laboratories after their audits, with a library of answers to IT non-compliances.

To find out more, discover TDNexLabs and TDMind, or contact our teams.

Insights

The laboratory, as seen by those who build it.

All resources
Perspective
October 2, 2026
Gloved hand holding a sample tube in the laboratory

COVID-19: how laboratories absorbed the surge in activity

PCR analyzers to integrate, connections to reconfigure, results to deliver fast: a look back at how laboratories and their LIS vendor coped with the health crisis.

Learn more
Perspective
October 2, 2026
Hands holding a tablet displaying data

Online results: the laboratory and the connected patient

Viewing test results online has become second nature. Security, patient autonomy, electronic ordering: how the laboratory organizes itself with TDPatient and TDWeb.

Learn more
Perspective
October 2, 2026
Nurse entering patient information on a laptop

Patient identification: integrating the INS in the laboratory

Since 1 January 2021, the INS has been mandatory to reference health data in France. What this changes for the laboratory, and how the LIS makes patient identification more reliable.

Learn more